Magnetic polyethyleneimine functionalized reduced graphene oxide as a novel magnetic solid-phase extraction adsorbent for the determination of polar acidic herbicides in rice
Department中科院西北特色植物资源化学重点实验室/甘肃省天然药物重点实验室
Li N(李娜)1,2; Chen J(陈娟)1; Shi YP(师彦平)1; Chen J(陈娟); Shi YP(师彦平)
2017
Source PublicationAnalytica Chimica Acta
ISSN0003-2670
Volume949Pages:23-34
Abstract

A novel magnetic polyethyleneimine modified reduced graphene oxide (Fe3O4@PEI-RGO) had been fabricated based on a self-assemble approach between positive charged magnetic polyethyleneimine (Fe3O4@PEI) and negative charged GO sheets via electrostatic interaction followed by chemical reduction of GO to RGO. The as-prepared Fe3O4@PEI-RGO was characterized by transmission electron microscopy (TEM), Fourier transform infrared spectrometry (FT-IR), X-ray diffraction (XRD), thermal gravimetric analyzer (TGA), vibrating sample magnetometer (VSM) and zeta potential analysis, and then was successfully applied to determine four phenoxy acid herbicides and dicamba in rice coupled with high performance liquid chromatography (HPLC). As a surface modifier of RGO, PEI not only effectually affected the surface property of RGO (e.g. zeta potential), but also changed the polarity of RGO and offered anion exchange groups to polar acidic herbicides, which would directly influence the type of adsorbed analytes. Compared with Fe3O4@PEI, Fe3O4/RGO and Fe3O4@PEI-GO, the as-prepared Fe3O4@PEI-RGO, integrating the superiority of PEI and RGO, showed higher extraction efficiency for polar acidic herbicides. Besides, the adsorption mechanism was investigated as well. It turned out that electrostatic interaction and π-π interaction were considered to be two major driving force for the adsorption process. Response surface methodology (RSM), a multivariate experimental design technique, was used to optimize experimental parameters affecting the extraction efficiency in detail. Under the optimal conditions, a satisfactory performance was obtained. The calibration curves were linear over the concentration ranging from 2 to 300 ng g−1 with correlation coefficients (r) between 0.9985 and 0.9994. The limits of detection (LODs) were in the range of 0.67–2 ng g−1. The recoveries ranged from 87.41% to 102.52% with relative standard deviations (RSDs) less than 8.94%. Taken together, the proposed method was an efficient pretreatment and enrichment procedure and could be successfully applied for selective extraction and determination of polar acidic herbicides in complex matrices.

KeywordMagnetic Polyethyleneimine Reduced Graphene Oxide Magnetic Solid-phase Extraction Polar Acidic Herbicides Adsorption Mechanism
Subject Area分析化学与药物化学
DOI10.1016/j.aca.2016.11.016
Funding Organizationthe National Nature Science Foundation of China (Nos. 21375136;21575150);the Scholar Program of West Light Project, Chinese Academy of Sciences
Indexed BySCI
If4.950
Language英语
Funding Project药物化学成分研究组
compositor第一作者单位
Citation statistics
Cited Times:101[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.licp.cn/handle/362003/20908
Collection中科院西北特色植物资源化学重点实验室/甘肃省天然药物重点实验室
Corresponding AuthorChen J(陈娟); Shi YP(师彦平)
Affiliation1.Key Laboratory of Chemistry of Northwestern Plant Resources of the CAS and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou, 730000, PR China
2.University of Chinese Academy of Sciences, Beijing, 100039, PR China
Recommended Citation
GB/T 7714
Li N,Chen J,Shi YP,et al. Magnetic polyethyleneimine functionalized reduced graphene oxide as a novel magnetic solid-phase extraction adsorbent for the determination of polar acidic herbicides in rice[J]. Analytica Chimica Acta,2017,949:23-34.
APA Li N,Chen J,Shi YP,陈娟,&师彦平.(2017).Magnetic polyethyleneimine functionalized reduced graphene oxide as a novel magnetic solid-phase extraction adsorbent for the determination of polar acidic herbicides in rice.Analytica Chimica Acta,949,23-34.
MLA Li N,et al."Magnetic polyethyleneimine functionalized reduced graphene oxide as a novel magnetic solid-phase extraction adsorbent for the determination of polar acidic herbicides in rice".Analytica Chimica Acta 949(2017):23-34.
Files in This Item:
File Name/Size DocType Version Access License
ACA-2017(LiN).pdf(3195KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Application Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Li N(李娜)]'s Articles
[Chen J(陈娟)]'s Articles
[Shi YP(师彦平)]'s Articles
Baidu academic
Similar articles in Baidu academic
[Li N(李娜)]'s Articles
[Chen J(陈娟)]'s Articles
[Shi YP(师彦平)]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Li N(李娜)]'s Articles
[Chen J(陈娟)]'s Articles
[Shi YP(师彦平)]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: ACA-2017(LiN).pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.