Selective determination of uric acid in the presence of ascorbic acid at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode
Department甘肃省天然药物重点实验室
Tang H(汤浩); Hu GZ(胡广志); Jiang SX(蒋生祥); Liu X(刘霞)
2009
Source PublicationJournal of Applied Electrochemistry
ISSN0021-891X
Volume39Pages:2323-2328
AbstractThe electrocatalytic behavior of uric acid has been investigated with a glassy carbon electrode modified with p-aminobenzene sulfonic acid through electrochemical polymerization. This resulting electrode shows an excellent electrocatalytic response to uric acid and ascorbic acid, with a peak-to-peak separation of 0.267 V in a 0.1 mol L-1 phosphate buffer solution (PBS) at pH 7.0. These results indicate that the proposed electrode can eliminate the serious interference of ascorbic acid, which coexists with uric acid in body fluids. Differential pulse voltammetry (DPV) was used for detecting uric acid with selectivity and sensitivity. The anodic peak current of uric acid was proportional to its concentration in the range of 1.2 9 10-7–8.0 9 10-4 mol L-1, with a detection limit of 4.0 9 10-8 mol L-1. The proposed method has been applied with satisfactory results to the determination of uric acid in human urine without any pretreatment.
KeywordGlassy Carbon Electrode Electro-polymerization Uric Acid Ascorbic Acid Selective Determination
Subject Area分析化学与药物化学
Funding Organizationthe National Natural Science Foundation of China (20527005, 20775084);the Natural Science Foundation of Gansu Province, China (3YS051-A25-022)
Indexed BySCI
Language英语
Funding Project药物分离材料研究组
Citation statistics
Cited Times:20[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.licp.cn/handle/362003/1183
Collection中科院西北特色植物资源化学重点实验室/甘肃省天然药物重点实验室
Corresponding AuthorJiang SX(蒋生祥)
Recommended Citation
GB/T 7714
Tang H,Hu GZ,Jiang SX,et al. Selective determination of uric acid in the presence of ascorbic acid at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode[J]. Journal of Applied Electrochemistry,2009,39:2323-2328.
APA 汤浩,胡广志,蒋生祥,&刘霞.(2009).Selective determination of uric acid in the presence of ascorbic acid at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode.Journal of Applied Electrochemistry,39,2323-2328.
MLA 汤浩,et al."Selective determination of uric acid in the presence of ascorbic acid at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode".Journal of Applied Electrochemistry 39(2009):2323-2328.
Files in This Item:
File Name/Size DocType Version Access License
Selective determinat(372KB) 开放获取LicenseView Application Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[汤浩]'s Articles
[胡广志]'s Articles
[蒋生祥]'s Articles
Baidu academic
Similar articles in Baidu academic
[汤浩]'s Articles
[胡广志]'s Articles
[蒋生祥]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[汤浩]'s Articles
[胡广志]'s Articles
[蒋生祥]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Selective determination of uric acid in the presence of ascorbic acid at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.